Entries Tagged as 'Blade Systems'

HP Proliant BL460c Gen9 HBA bug

FACT : HP ProLiant BL460c Gen9 Server
FACT : HP FlexFabric 20Gb 2-port 650FLB Adapter
FACT : ESX 5.5 U3
FACT : Updated to lates OA and VC FC version (4.45)
SYMPTOM : Storage path may disappear after 650FLB Firmware upgrade to
SYMPTOM :Problem is seen with Virtual Connect FLexfabric 10/24 and 20/40 modules.
SYMPTOM : No network avaiable during install of ESXi (HP version), so fails.
Upgrading with latest firmware ( on 650 FLB may cause the path to the storage to disappear. This issue may occur when using the latest SPP Version 2015.06.0.
CAUSE: This issue only occurs because of the 650FLB firmware version
FIX: This issue is currently under investigation
As Workaround downgrade the firmware to 10.2.477.23 using (SPP) Version 2015.04.0 Or Reduce the uplink to 1 per Virtual connect SAN fabric or OneView Fibre Channel Uplink set.
Do this by applying the interactive mode and ONLY “upgrade” the Emulex LOM firmware back down to 10.2.477.23.