Entries Tagged as ''

Cleaning Brocarde Switch Zoning

There are moments you need to get the old zoning out of a Brocade SAN switch. This could be, because you are re-using an older switch in your enviroment, or maybe you have been working on your fabric without noticing that you had a Fragmented Fabric.

To clean the config do following steps:

switchDisable
cfgDisable 
cfgClear 
cfgSave
switchEnable

.. and voila!!! A brand new switch.!

80080005 Server execution failed

In one instance we encountered following error on a VEEAM backup environment, where all backup’s failed in the same session. also manually restarting the jobs gave this error:

Unable to subscribe to guest processing components: Retrieving the COM class factory for component with CLSID {D2E3C73F-841A-46B0-A93F-956CCABD3B11} failed due to the following error: 80080005 Server execution failed (Exception from HRESULT: 0x80080005 (CO_E_SERVER_EXEC_FAILURE))

After investigation it seemed that intl.dll was missing in the …\Veeam\Backup and Replication\Backup\VSS folder.

Replacing it fixed the problem.